FIRE GLASS SPEC TABLE
PRODUCT |
THICKNESS (mm) |
INTEGRITY (mins) |
INSULATION (mins) |
WEIGHT (kg/m2) |
APPLICATION |
SUBSTANCE |
GWPP clear |
7 |
30 |
0 |
16 |
Int/Ext |
Wired |
GWC texture |
7 |
30 |
0 |
16 |
Int/Ext |
Wired |
Pyroguard EW 30 |
7.2 |
30 |
0 |
17 |
Int/Ext |
Laminated |
Pyroguard EW 60 |
11.4 |
60 |
0 |
26.7 |
Int/Ext |
Multi-Lam |
Pyroguard EI 30 INT |
15 |
60 |
30 |
37.6 |
Internal |
Multi-Lam |
Pyroguard EI 30 EXT |
19 |
60 |
30 |
50 |
External |
Multi-Lam |
Pyroguard EI 60 INT |
23 |
60 |
60 |
57.6 |
Internal |
Multi-Lam |
Pyroguard EI 60 EXT |
27 |
60 |
60 |
61.8 |
External |
Multi-Lam |
E – INTEGRITY |
EW – RADIATION CONTROL |
EI – INSULATION |
No flames |
No flames |
No flames |
No gas |
No gas |
No gas |
No heat reduction |
No heat reduction |
No heat |
Maximum sizes vary and can depend on frame design, please contact us for information on large or shaped pieces.
It is essential that all fire glass is glazed into appropriate frame system and that the method of glazing confirms to manufacturers guidelines.
DISCLAIMER: It is the sole responsibility of the end installer to ensure the correct glass is used and fitted correctly. Chelsea Glass Ltd can only offer advice, if necessary professional bodies should be contacted.