FIRE GLASS
TECHNICAL INFORMATION - FIRE GLASS
7mm GWPP clear (Georgian wired polished plate)
A non-insulated clear wire glass, for internal or external use, with a 30 minute integrity fire rating.
7mm GWC texture (Georgian wired cast)
A non-insulated obscure wired glass, for internal or external use, with a 30 minute integrity fire rating.
7.2mm Pyroguard
A non-insulated, clear 3-ply laminated glass with 30 minute integrity, for internal or external use. Class B impact safety (UK) and class 2B2 (Europe)
11.4mm Pyroguard
A non-insulated, clear 5-ply laminated glass with 60 minute integrity, for internal or external use. Class B impact safety (UK) and class 2B2 (Europe)
15mm Pyroguard Insulation (Internal use) 19mm Pyroguard Insulation (External use)
A clear 7-ply laminated glass with 60 minute integrity and 30 minute insulation, for internal and external use. Class A impact safety (UK) and class 1B1 (Europe)
23mm Pyroguard Insulation (Internal use) 27mm Pyroguard Insulation (External use)
A clear 11-ply laminated glass with 60 minute integrity and 30 minute insulation, for internal and external use. Class A impact safety (UK) and class 1B1 (Europe)
Sealed Units
All the above glass can be used to form an insulated glass unit using a toughened glass.
INFORMATION NEEDED WHEN CHOOSING FIRE GLASS
Integrity
Length of time a glass will prevent the passage of smoke and flames.
Insulation
Length of time a glass will prevent the transmission of conductive and radiative heat.
Application
Whether glass is to be glazed internally or externally
Frame
Determines glass to be used (Larger sizes can be fitted into timber frames as opposed to steel).
Size of panels
If the manufacturers maximum tested size is exceeded, the fire resistant properties of the product cannot be guaranteed.